B4X
B4X
Read an SSH Channel with a Byte Threshold
See more SSH Examples
Demonstrates the Chilkat Ssh.ChannelReadAndPoll2 method, which works like ChannelReadAndPoll but also returns once newly processed data brings the total buffered data to or above a byte threshold. The arguments are the channel number, the poll timeout, and the threshold.
The integer return value is -1 on error, -2 if nothing arrived before the timeout, 0 if EOF or channel close was processed, or — when greater than 0 — the total bytes currently buffered for the channel (not the bytes newly received by this call).
Background: The threshold makes it practical to stream large output in manageable chunks instead of buffering an entire multi-megabyte result. Treat it as a return threshold, not a hard cap: a complete SSH packet is buffered as a unit, so the amount returned can exceed what you asked for. Data already buffered before the call does not by itself trigger an immediate return.
Chilkat B4X Downloads
Dim success As Boolean = False
' Demonstrates the Ssh.ChannelReadAndPoll2 method, which works like ChannelReadAndPoll but also
' returns once the total buffered data reaches or exceeds a byte threshold. The 1st argument is
' the channel number, the 2nd is the poll timeout, and the 3rd is the byte threshold.
Dim ssh As ChilkatSsh
ssh.Initialize("ssh")
Dim sshPort As Int = 22
success = ssh.Connect("ssh.example.com", sshPort)
If success = False Then
Log(ssh.LastErrorText)
Return
End If
' Normally you would not hard-code the password in source. You should instead obtain it
' from an interactive prompt, environment variable, or a secrets vault.
Dim password As String = "mySshPassword"
success = ssh.AuthenticatePw("mySshLogin", password)
If success = False Then
Log(ssh.LastErrorText)
Return
End If
Dim channelNum As Int = ssh.OpenSessionChannel
If channelNum < 0 Then
Log(ssh.LastErrorText)
Return
End If
' Start a shell WITHOUT requesting a PTY. Without a PTY the shell sees it is connected to a
' raw data pipe and enters non-interactive mode: it suppresses the command prompt, does not
' echo typed commands back, and skips interactive login scripts. The output is therefore
' clean and easily parseable -- but because no prompt is ever sent, code must not wait for
' one. Instead, have each command print a predictable marker, or wait for EOF / channel close.
success = ssh.SendReqShell(channelNum)
If success = False Then
Log(ssh.LastErrorText)
Return
End If
success = ssh.ChannelSendString(channelNum, "cat /var/log/syslog" & Chr(10), "utf-8")
If success = False Then
Log(ssh.LastErrorText)
Return
End If
' Return when output goes quiet for 500ms, or once about 64KB has been buffered. The
' threshold is not a hard buffer limit -- a whole SSH packet may push the total above it.
Dim pollTimeoutMs As Int = 500
Dim maxNumBytes As Int = 65536
' The return value is: -1 on error, -2 if nothing arrived before the timeout, 0 if EOF or
' channel close was processed, or the total number of buffered bytes when greater than 0.
Dim result As Int = ssh.ChannelReadAndPoll2(channelNum, pollTimeoutMs, maxNumBytes)
If result = -1 Then
Log(ssh.LastErrorText)
Return
End If
If result = -2 Then
Log("No channel data arrived before the timeout.")
End If
If result = 0 Then
Log("EOF or channel close was processed. Buffered data may still remain.")
End If
If result > 0 Then
Log("Total bytes buffered: " & result)
End If
Dim output As String = ssh.GetReceivedText(channelNum, "utf-8")
If ssh.LastMethodSuccess = False Then
Log(ssh.LastErrorText)
Return
End If
Log(output)
ssh.Disconnect